2024/11/04 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:115 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2024/11/03 0.5770 1.01673 1.0711 00.3283 00.0000 00.0000 96.6568 01.7651 00.1486 00.0100 00.0122 00.0000 00.0030 00.0019 00.0012 00.0009 00.0004 00.0000 CUSTER ST @ LINE AD ST1 2024/11/03 0.5707 1.01289 0.4107 00.9670 00.0000 00.0000 97.0402 01.5308 00.0477 00.0013 00.0020 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2024/11/03 0.5875 1.02984 0.7409 01.0335 00.0000 00.0000 94.1079 03.9063 00.1810 00.0087 00.0139 00.0000 00.0026 00.0021 00.0012 00.0009 00.0004 00.0000 CHANDLER ST DISCHARGE G 2024/11/03 0.5906 1.03417 0.7876 00.9989 00.0000 00.0000 93.5041 04.4996 00.1877 00.0072 00.0089 00.0000 00.0017 00.0013 00.0011 00.0008 00.0004 00.0000 FM 63 - Columbia GC @ 2 2024/11/03 0.6001 1.07352 0.1970 00.4293 00.0000 00.0000 91.2704 07.7380 00.3037 00.0190 00.0316 00.0000 00.0048 00.0023 00.0016 00.0012 00.0005 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.