2024/12/19 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:115 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2024/12/18 0.5824 1.01955 1.2688 00.3726 00.0000 00.0000 95.6915 02.5166 00.1264 00.0077 00.0097 00.0000 00.0023 00.0017 00.0010 00.0007 00.0003 00.0000 CUSTER ST @ LINE AD ST1 2024/12/18 0.5735 1.01505 0.4807 00.9989 00.0000 00.0000 96.5526 01.8878 00.0747 00.0019 00.0031 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2024/12/18 0.5952 1.04305 0.7902 00.9005 00.0000 00.0000 92.5659 05.5340 00.1898 00.0063 00.0083 00.0000 00.0016 00.0011 00.0009 00.0007 00.0003 00.0000 CHANDLER ST DISCHARGE G 2024/12/18 0.5969 1.04499 0.7674 00.9708 00.0000 00.0000 92.2049 05.8428 00.1958 00.0064 00.0074 00.0000 00.0014 00.0010 00.0007 00.0005 00.0002 00.0000 FM 63 - Columbia GC @ 2 2024/12/18 0.6037 1.07987 0.1895 00.4024 00.0000 00.0000 90.6703 08.2711 00.3738 00.0297 00.0419 00.0000 00.0084 00.0053 00.0033 00.0024 00.0012 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.