2026/02/01 ENABLE GAS TRANSMISSION, LLC PAGE: 1
MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020
TIME: 15:01:150
Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane %
O2 C1 C2 C3 C5 C6 C7 C8 C9
----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ----------
BAY CHECK GC @ 170610 2026/01/31 0.5904 1.02914 1.2721 00.5404 00.0000 00.0000 94.0803 03.9162 00.1705 00.0066 00.0081 00.0000 00.0018 00.0013 00.0010 00.0007 00.0003 00.0000
CUSTER ST @ LINE AD ST1 2026/01/31 0.5920 1.03659 0.8308 00.9236 00.0000 00.0000 93.2800 04.7149 00.2432 00.0035 00.0037 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000
GLENDALE CEGT TO MRT @ 2026/01/31 0.5997 1.04882 0.7847 00.9818 00.0000 00.0000 91.7387 06.2231 00.2374 00.0074 00.0114 00.0000 00.0023 00.0018 00.0052 00.0038 00.0018 00.0000
CHANDLER ST DISCHARGE G 2026/01/28 0.6026 1.05509 0.7886 00.8750 00.0000 00.0000 91.1623 06.8662 00.2874 00.0069 00.0073 00.0000 00.0014 00.0011 00.0016 00.0011 00.0005 00.0000
FM 63 - Columbia GC @ 2 2026/01/31 0.5852 1.01641 1.5795 00.3440 00.0000 00.0000 95.7811 01.9641 00.2039 00.0589 00.0310 00.0000 00.0143 00.0050 00.0083 00.0062 00.0030 00.0000
The information displayed above reflects daily average gas quality readings
taken at key locations on the EGT system. The dates shown above are the
dates of the readings. The readings are taken daily, and information from such
readings is posted on the first day thereafter. If on any reading day there
are problems retrieving the data, the last reported readings will remain
posted until such time as new readings are obtained. Due to factors such as
equipment failure, sample contamination and human error, the information
displayed above may not be completely accurate.